Machining Stainless Steel is the use of CNC machining out, including drilling, boring, cutting, turning, screw, etc.. Machining stainless steel commonly used materials: sus303304316.stainless steel has a very high hardness after machining, easy deformation, so in the process of rough machining to eliminate stress, and then finished. Surface treatment is generally passivation, we have specialized laboratories to test products, and ensure that each size to meet the requirements of the drawings, including the machining stainless steel application in various industries: automobile, ship, crane, medical equipment, industrial automation equipment.
Of course,we also accept the custom machining,welcome to contact us. Machining Stainless Steel Machining Stainless Steel,High Precision Machining Stainless Steel,Cnc Machining Stainless Steel,Stainless Steel Machining,Steel Machining Hong Kong RYH CO., LTD , https://www.bldcncmachining.com
OX2/231 is based on the equal pressure method, and is professional applicable to the determination of oxygen transmission rate of film and package products, including plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.
Features
Applications
Â
Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
Including various sorts of engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
Including plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups
Specifications
Â
Specifications
Film Test
Test Range
0.01 ~ 1000 cm3/m2·d (standard)
0.1 ~ 10,000 cm3/m2·d (optional)0.0001 ~ 10 cm3/pkg·d (standard)
Number of Specimens
1 ~ 3
Resolution
0.01 cm3/m2·d
0.0001 cm3/pkg·d
Temperature Range
15°C ~ 55°C (optional)
/
Temperature Accuracy
±0.1°C
/
Humidity Range
0%RH, 15%RH ~ 90%RH, 100%RHÂ
(optional)
Humidity Accuracy
±1%RH
Test Gas
O2Â and air (outside of supply scope)
Test Area
50 cm2
/
Thickness
≤3 mm (customization is available for other thickness)
/
Specimen Size
108 mm x 108 mm
Test in 100% O2: Specimen should be smaller than Ф120 mm and lower than 360 mm
Test in the Air: No size limitation Bottles: the inner diameter should be bigger than Ф8 mm, outer diameter should be smaller than Ф42 mm (Standard) Bags or Boxes: Supported by accessories
Carrier Gas
High purity nitrogen with more than 99.999% concentration
(outside of supply scope)
StandardsISO 15105-2, GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, JIS K7126-2, YBB00082003
Paper Plastic Composite Film Oxygen Transmission Rate Test System
OX2/231 is based on the equal pressure method, and is professional applicable to the determination of oxygen transmission rate of film and package products, including plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.
Features
Applications
Â
Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
Including various sorts of engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
Including plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups
Specifications
Â
Specifications
Film Test
Test Range
0.01 ~ 1000 cm3/m2·d (standard)
0.1 ~ 10,000 cm3/m2·d (optional)0.0001 ~ 10 cm3/pkg·d (standard)
Number of Specimens
1 ~ 3
Resolution
0.01 cm3/m2·d
0.0001 cm3/pkg·d
Temperature Range
15°C ~ 55°C (optional)
/
Temperature Accuracy
±0.1°C
/
Humidity Range
0%RH, 15%RH ~ 90%RH, 100%RHÂ
(optional)
Humidity Accuracy
±1%RH
Test Gas
O2Â and air (outside of supply scope)
Test Area
50 cm2
/
Thickness
≤3 mm (customization is available for other thickness)
/
Specimen Size
108 mm x 108 mm
Test in 100% O2: Specimen should be smaller than Ф120 mm and lower than 360 mm
Test in the Air: No size limitation Bottles: the inner diameter should be bigger than Ф8 mm, outer diameter should be smaller than Ф42 mm (Standard) Bags or Boxes: Supported by accessories
Carrier Gas
High purity nitrogen with more than 99.999% concentration
(outside of supply scope)
StandardsISO 15105-2, GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, JIS K7126-2, YBB00082003
Model NO.: OX2/231
Power Source: AC220V
Certifications: ISO Ce
Warranty: 12 Months
After-Service: Online, in Field
Trademark: Labthink
Transport Package: Veneer Case
Origin: Shandong
Model NO.: OX2/231
Power Source: AC220V
Certifications: ISO Ce
Warranty: 12 Months
After-Service: Online, in Field
Trademark: Labthink
Transport Package: Veneer Case
Origin: Shandong
Paper Plastic Composite Film Oxygen Transmission Rate Test SystemPackage Test
(customization available)
Package Test
(customization available)