1. Flexible: It can quickly reach the suspected epidemic area and complete the deployment within 60 seconds; 2. Safety: The vehicle body is isolated under positive pressure to ensure the safety of medical personnel; 3.: It can collect no less than 1300 samples per day; 4. Wisdom: 5G interconnection, data can be synchronized with the health system in real time Body system 1 Car body assembly Car body frame, light body skin, heat insulation material set 1 2 Double open tailgate Aluminum alloy, with door lock mechanism and glass window set 1 3 Body appearance Customized according to customer requirements set 1 Electrical system 4 Inverter With charging function, pure sine wave 2000 W set 1 5 External power system 2 2 0V/16A, white set 1 6 AC/DC socket Five-hole USB socket Group 3 7 Car refrigerator Intel 50L refrigerator tower 1 8 flashlight LED form, 12V Cup 4 9 Exterior lights LED form, 12V Cup 2 10 Overhead car air conditioner Cooling capacity 4000, heating capacity 3000 set 1 1 1 Walkie-talkie system 12V, intercom for each station set 2 1 2 Control System set 1 1 3 surveillance system IT storage , independent recording of each work area set 1 Disinfection facility 1 4 UV disinfection lamp Timed, effective antivirus Cup 1 1 5 Ozone generator Ozone amount 4G/H, equipped with ozone concentration sensor set 1 16 Plasma disinfection system Realize the coexistence and disinfection of man and machine set 1 Protection system 17 Fresh air filtration system Top-mounted type, with filtering device set 1 18 Positive pressure control system Fresh air volume and positive pressure monitoring set 1 19 Exhaust filter system Dedicated for sample disposal area, including filtering device set 2 20 Isolation gloves For sampling set 1 2 1 Office isolation screen Transparent material, easy to clean set 1 Cabinet system  2 2 Middle partition Composite material set 1 2 3 Registration desk Composite material set 2 2 4 Sampling workbench Composite material set 2 2 5 Sample disposal cabinet Composite material set 2 26 Swivel seat Sampling area use set 2 27 Transfer slot Use of registration area set 2 Interior seat system 28 Inspection cabin interior Polymer material, anti-corrosion, easy to clean set 1 29 Medical floor Overall plastic, waterproof, anti-corrosion, abrasion resistance, mildew proof, environmental protection, fire prevention set 1 30 Staff seat Rotatable Only 2 Other changes 31 Sink system Electric, including clean water tank, sewage tank set 1 32 Dirt bucket 20L, waste Piece 4 33 Fire extinguisher Dry powder type, the inspection cabin is equipped with a 2kg dry powder fire extinguisher, and the cockpit is equipped 1 2kg dry powder fire extinguisher Piece 2 34 On-board water dispenser Multi-purpose cold and hot type for medical staff (optional) set 1 35 DR20
GOLMA-COOL ventilation was founded in 2005, we are the special manufacturer in the field of ventilation system. Having been engaged in HVAC/R industry for more than 10 years, we have accumulated rich product knowledge and experience for below productions: *Flexible air ducting*Aluminum Semi Rigid flexible duct*Flexible Duct Connector*Insulation pins*Duct fittings*Duct hardware*Pipe clamps and ventilation clamps*Air valve and diffuser *HVAC TAPE*A/C Brackets We possesses excellent manufacturing capability in the market to provide consistently high quality products. With abundant capital, a professional and experienced team and supports from our strong strategic partners .
Dial Air Regulators,Dial air regulator,Dialflow Regulator,Separated Type Dial Regulator Ningbo Gemu Ventilation Technology Compnay Limited , https://www.golmacool.com
How many times can n95 masks be reused? In high-risk environments, the duration of use of n95 masks should not exceed 4 hours. If the mask is contaminated, deformed, damaged, or breathing hard, it needs to be replaced immediately. In this case, the masks are mostly disposable. Chengli nucleic acid sampling vehicle is a special anti-epidemic artifact for the Epidemic Prevention Center, which is convenient and fast to move, expensive and fast, and protects the safety of the whole people.
Ford Transit V362 nucleic acid sampling vehicle, price, pictures, manufacturer's phone number 138 7288 1997 Manager Liang
Ford V362 nucleic acid sampling vehicle has the following characteristics:
Dial Regulators
Dial Regulator
1/4" and 3/8" dial regulator are the most popular models on the market.
Minimize air leakage and reduce rattle. A wing nut locks the damper in position.
The dial shows the damper position at a glance.
Can be mounted easily on round or rectangular ducts.
For dampers up to :250mm mm (10") Diameter
Set Includes.
Dial parts with handle
Wing nut ,washer & bolt
1/4"spring loaded end spindle
1/4" Square spindle
GOLMA-COOL dedicates to develop continuous innovation technology, to keep our range of products up to date with the current trends and developments of HVAC/R industry.We are assure you with high quality, competitive price, fast delivery and efficient service all the time. We are here with you all the time.
Pharyngeal swab sampling vehicle_Sampling vehicle anti-epidemic pioneer_Ford v362 nucleic acid sampling vehicle_Nucleic acid sampling vehicle_CDC sampling vehicle configuration_picture